Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
CID FMI CODE
Test or Inspection
Corrective Action
1707-06 Proportional Sole-
No Continuity - Proceed to step 15.
noid Valve (Left Drive Motor)
0283), test for continuity between
Current Above Normal -
pin 58 on platform harness ECM
harness (WP 0150, WP 0155).
Continued
Ensure all harness connectors are
Figure 217) and all other pins on
reconnected. Verify proper operation
platform harness ECM J1 connec-
of machine (TM 5-2410-240-10).
No Continuity - Replace machine
0283), test for continuity between
ECM (WP 0147, WP 0149). Ensure all
pin 58 on platform harness ECM
harness connectors are reconnected.
Verify proper operation of machine
Figure 217) and all other pins on
(TM 5-2410-240-10).
platform harness ECM J2 connec-
harness (WP 0150, WP 0155).
Ensure all harness connectors are
reconnected. Verify proper operation
of machine (TM 5-2410-240-10).
N OT E
1707-13 Proportional Sole-
noid Valve (Left Drive Motor)
Always inspect harness connectors th t are involved in circuit. Poor
a
Out of Calibration
connections can often be the cause of an electrical circuit problem. Ver-
ify that all connections in circuit are clean, secure, and connections are
in good condition. If a problem with connection is found, correct problem
and verify diagnostic code is active before performing this procedure.
Tag wiring harnesses to aid installation.
1707-13 Code Active - Proceed to
machine control ECM and check
step 2.
No Codes Active - The problem does
not exist at this time. Resume normal
operation.
2. Left drive motor proportional sole- Perform Hydrostatic Pump and
N OT E
1708-03 Proportional Sole-
noid Valve (Right Drive
Always inspect harness connectors that are involved in circuit. Poor
Motor) Voltage Above Nor-
connections can often be the cause of an electrical circuit problem.
mal
Verify that all connections in circuit are clean, secure, and connections
are in good condition. If a problem with connection is found, correct
problem and verify diagnostic code is active before performing this
procedure.
Tag wiring harnesses to aid installation.
1708-03 Code Active - Proceed to
step 2.
machine control ECM and check
No Codes Active - The problem does
not exist at this time. Resume normal
operation.