TM 5-2410-241-23-2
0164
REMOVAL CONTINUED
N OT E
Note cable routing to aid installation.
Tag and mark all electrical connections to aid installation.
11. Remove tiedown straps (Figure 4, Item 2) from starter cable (Figure 4, Item 1). Discard tiedown straps.
12. Remove starter cable (Figure 4, Item 1) from machine.
Figure 4. Starter Cable.
0164
END OF TASK
CLEANING AND INSPECTION
000164
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0295).
END OF TASK