TM 5-2410-240-23-1
0021
Table 1. Cab Troubleshooting Without Codes. - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. HVAC Blower Motor Does Not
11. Turn battery disconnect switch
Function in One or More Speeds
and ignition switch to ON posi-
- Continued
tion (TM 5-2410-240-10).
12. Turn blower fan switch to
medium-high fan speed (TM
5-2410-240-10).
Voltage Less Than Specified
sure for voltage (WP 0283)
Range - Proceed to step 17.
between harness connector
Voltage Within Specified Range
- Proceed to step 14.
terminal 2 and terminal 4.
There should be approximately 18
to 26 volts.
14. Turn ignition switch and bat-
tery disconnect switch to OFF
position (TM 5-2410-240-10).
15. Disconnect harness connec-
43) from high fan relay (WP
16. Reconnect harness connector
Replace medium-high fan relay
harness connectors are recon-
Figure 49).
nected. Verify proper operation of
machine (TM 5-2410-240-10).
17. Turn ignition switch and bat-
tery disconnect switch to OFF
position (TM 5-2410-240-10).
18. Disconnect harness connec-
44) from medium-high fan
19. Reconnect harness connector
Figure 49).
No Continuity - Replace lower
cab wiring harness (WP 0228).
between harness connector
Ensure all harness connectors are
reconnected. Verify proper opera-
terminal 2 and cab ground.
tion of machine (TM 5-2410-240-
10).
0021-26