TM 5-2410-240-23-1
0021
Table 1. Cab Troubleshooting Without Codes. - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. HVAC Blower Motor Does Not
6. Turn ignition switch and bat-
Function in One or More Speeds
tery disconnect switch to OFF
- Continued
position (TM 5-2410-240-10).
7. Disconnect harness connec-
44) from high fan relay (WP
for continuity (WP 0283)
cab wiring harness (WP 0228).
Ensure all harness connectors are
Figure 45) terminal 1 and har-
reconnected. Verify proper opera-
tion of machine (TM 5-2410-240-
0018, Figure 44) terminal 4.
10).
9. Disconnect harness connec-
43) from medium-high fan
10. Connect harness connector C-
ure 49).
11. Turn battery disconnect switch
and ignition switch to ON posi-
tion (TM 5-2410-240-10).
12. Turn blower fan switch to
medium-high fan speed (TM
5-2410-240-10).
Voltage Less Than Specified
sure for voltage (WP 0283)
Range - Proceed to step 17.
between harness connector
Voltage Within Specified Range
- Proceed to step 14.
terminal 1 and terminal 4.
There should be approximately 18
to 26 volts.
14. Turn ignition switch and bat-
tery disconnect switch to OFF
position (TM 5-2410-240-10).
15. Disconnect harness connec-
43) from high fan relay (WP
0021-34