Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  552    553    554    555    556  557  558    559    560    561    562  
img
. . . . . . . . .
TM 5-2410-240-23-1
0020
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
CID FMI CODE
Test or Inspection
Corrective Action
1706-03 Proportional Sole-
14. Using digital multimeter (WP
No Continuity - Replace machine
noid Valve (Reverse Right
0283), test for continuity between
ECM (WP 0147, WP 0149). Ensure all
Drive Pump) Voltage Above
pin 52 on platform harness ECM
harness connectors are reconnected.
Normal - Continued
J1 connector PL-C4 (WP 0018,
Verify proper operation of machine
Figure 217) and all other pins on
(TM 5-2410-240-10).
platform harness ECM J2 connec-
Continuity - Replace platform wiring
tor PL-C5 (WP 0018, Figure 218).
harness (WP 0150, WP 0155).
Ensure all harness connectors are
reconnected. Verify proper operation
of machine (TM 5-2410-240-10).
N OT E
1706-05 Proportional Sole-
noid Valve (Reverse Right
Always inspect harness connectors that are involved in circuit. Poor
Drive Pump) Current Below
connections can often be the cause of an electrical circuit problem.
Normal
Verify that all connections in circuit are clean, secure, and connections
are in good condition. If a problem with connection is found, correct
problem and verify diagnostic code is active before performing this
procedure.
Tag wiring harnesses to aid installation.
1706-05 Code Active - Proceed to
1. Connect MSD (WP 0016). Select
step 2.
machine control ECM and check
for diagnostic codes (WP 0013).
No Codes Active - The problem does
not exist at this time. Resume normal
operation.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
3. Disconnect pump harness RH
reverse pump solenoid connector
PH-C5 (WP 0018, Figure 209)
from RH reverse pump solenoid.
4. Install a jumper wire between pins
1 and 2 on pump harness RH
reverse pump solenoid connector
PH-C5 (WP 0018, Figure 209).
5. Check for diagnostic codes (WP
1706-05 Code Active - Proceed to
0013).
step 6.
1706-06 Code Active - Replace RH
reverse pump solenoid (WP 0132).
Ensure all harness connectors are
reconnected. Verify proper operation
of machine (TM 5-2410-240-10).
6. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
0020-109