Table 1. Cab Troubleshooting Without Codes. - Continued.
Figure 51. Flood Lamp and Bulb Connector Terminals.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  748    749    750    751    752  753  754    755    756    757    758  
img
. . . .
TM 5-2410-240-23-1
0021
Table 1. Cab Troubleshooting Without Codes. - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
7. Rear Flood Lamp(s) Will Not
1. Disassemble flood lamp (WP
Work - Continued
0257).
2. Using digital multimeter, mea-
Resistance Less Than 0.3 Ohms
- Proceed to step 3.
sure resistance (WP 0283)
between flood lamp terminal 1
Resistance 0.3 Ohms or Greater
- Replace flood lamp (WP 0257).
and bulb terminal 1 (Figure
51).
Connect HL-C1 (WP 0018, Figure
175) on C-C101 (WP 0018, Figure
46) (WP 0229).
Connect C-C31 (WP 0018, Figure
28) on flood lamp relay (WP 0018,
Figure 55).
For D6K Dozer with Ripper, install
ripper operation control handle
(WP 0218). For D6K Dozer with
Winch, install winch operation
control handle (WP 0217).
Verify proper operation of flood
lamps (TM 5-2410-240-10).