TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2212-05 Auxiliary Valve #1
0283), measure resistance
Proceed to Test Step 4.
Below Normal - Continued
between PL-C2 terminal 40 (WP
0018, Figure 215) and PL-C18
Replace platform wiring harness: with
Ripper (WP 0150); with Winch (WP
226).
0155).
Connect chassis wiring harness con-
nector CH-C2 on auxiliary valve #1
For D6K Dozer with Ripper, install
rear plate on machine (WP 0196). For
D6K Dozer with Winch, install rear
bottom guards on machine (WP
0156).
Proceed to step 5.
Code 2212-05 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 2212-05 is not active.
Code 2212-05 Not Active - Trouble-
shooting complete.
0023-198