0228
REMOVAL CONTINUED
N OT E
Note position of washers to aid installation.
12. Remove three bolts (Figure 6, Item 2), six washers (Figure 6, Item 1), and cover (Figure 6, Item 3) from cab
(Figure 6, Item 4).
Figure 6. Fuse Panel Side Cover.
0228
13. Twist collar (Figure 7, Item 1) and disconnect connector (Figure 7, Item 2) from harness connector
(Figure 7, Item 5).
14. Remove nut (Figure 7, Item 3), washer (Figure 7, Item 4), and harness connector (Figure 7, Item 5) from fuse
panel (Figure 7, Item 6).
Figure 7. Fuse Block Harness Connector.