Figure 16. 24V to 12V Power Converter.
Figure 20. Ground Wires.

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  501    502    503    504    505  506  507    508    509    510    511  
img
.
TM 5-2410-240-23-3
0228
REMOVAL CONTINUED
27. Loosen bolt (Figure 18, Item 3) and disconnect electrical connector (Figure 18, Item 4).
28. Remove four bolts (Figure 18, Item 2), washers (Figure 18, Item 1), and electrical connector (Figure 18, Item 4)
from cab (Figure 18, Item 5).
Figure 18. Cab Wiring Harness Main Connector.
0228
29. Open left rear access door (TM 5-2410-240-10).
30. Disconnect electrical connectors (Figure 19, Items 1, 2 and 3) from machine.
Figure 19. A/C Connectors.
0228
0228-12