CAB REAR FLOOD LAMP SERVICE
Figure 2. Flood Lamp Grid and Mounting Bracket.

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  901    902    903    904    905  906  907    908    909    910    911  
img
.
TM 5-2410-240-23-3
0257
REMOVAL
000257
N OT E
Perform steps 1 through 5 to remove left flood lamp. Repeat steps 1 through 9 for right
flood lamp.
Tag electrical connector to aid installation.
Note location of tiedown sraps to aid installation.
t
1. Remove tiedown strap (Figure 1, Item 1) and disconnect cab wiring harness connector (Figure 1, Item 6) from
flood lamp (Figure 1, Item 5).
2. Remove two bolts (Figure 1, Item 3), washers (Figure 1, Item 2), and grid (Figure 1, Item 4) with flood lamp
(Figure 1, Item 5) from cab (Figure 1, Item 7). Discard tiedown strap.
Figure 1. Cab Rear Flood Lamp.
0257
0257-2