TM 5-2410-241-10
0012
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.
0012
LOCATION
ITEM TO
CHECK/
NOT FULLY MISSION
ITEM
MAN-
SERVICE
PROCEDURE
CAPABLE IF:
NO.
INTERVAL HOURS
26
Before
Dozer Blade
a. Start engine and run at low idle
b. Move the right joystick to most Blade float indicator does
forward detent. Blade float indicator not come on.
should be ON in indicators and
gauges display.
27
Before
Action Lamp
a. Monitor action lamp and auxiliary
and Auxiliary
action lamp.
Action Lamp
b. If action lamp or auxiliary action Action light or auxiliary
lamp comes ON and stays on,
action lamp comes on and
machine needs service.
stays on.
28
Before
Digital
With engine running, observe the
Information shows machine
Displays and two digital displays and the Messen- is not operating properly or
Messenger Dis- ger Display.
Messenger is not
play
functioning.
29
Before
Hydraulic
Perform a functional check of
Class III oil leak is evident.
Controls
hydraulic systems: blade lift/lower,
Any hydraulic system or
blade tilt, winch, and ripper
function does not operate
properly.
30
Before
Lights
Check operation of all flood lights
Any lights inoperative if
required for mission.
31
Before
Wipers and
Operate all wipers and washers to Wipers and washers not
verify correct operation (WP 0004). operating if required for
Washers
mission.
32
Before
Backup Alarm a. Verify that backup alarm
Backup alarm does not
functions when left joystick is moved function.
and Horn
to reverse position.
b. Check operation of horn.
Horn does not function.
33
During
Service Brake Move machine forward and test ser- Brakes DO NOT slow/stop
Pedal
vice brakes.
machine or pedal binds
when pedal is depressed.
Check decelerator pedal for proper Machine does not slow or
34
During
Decelerator
pedal binds when pedal is
function and for binding and
Pedal
depressed.
obstructions.
0012-18