TM 5-2410-241-23-2
0066
INSTALLATION
00066
N OT E
Install electrical connectors as tagged during removal.
1. Install fitting (Figure 1, Item 2) on air cleaner housing (Figure 1, Item 1).
2. Install new O-ring (Figure 1, Item 3) on fitting (Figure 1, Item 2).
3. Install turbocharger inlet pressure sensor (Figure 1, Item 7) on fitting (Figure 1, Item 2).
4. Connect connector (Figure 1, Item 4) on connector (Figure 1, Item 6).
5. Install new tiedown strap (Figure 1, Item 5) on connector (Figure 1, Item 6).
END OF TASK
FOLLOW-ON TASKS
00066
Verify correct operation of machine (TM 5-2410-241-10).
END OF TASK
END OF WORK PACKAGE
0066-3/(4 blank)