TM 5-2410-241-23-3
0272
WARN I N G
DO NOT disconnect or remove any hydraulic system hoses, tubes, or fittings unless
engine is shut down and hydraulic system pressure has been relieved. Tighten all
connections before applying pressure. Escaping hydraulic fluid under pressure can
penetrate skin.
At operating temperature, hydraulic oil is hot. Allow hydraulic oil to cool before removing
any hydraulic fitting.
To prevent injury to personnel, wear protective eye covering and gloves.
Failure to follow these warnings may result in injury or death to personnel.
C AU T I O N
Cap all hydraulic fittings, hoses, and tube ends along with component connections during
removal to protect against contamination. Failure to follow this caution may cause damage
to equipment.
N OT E
Tag all hoses and fittings to aid installation.
Use a container to catch any fluid that maydrain from hoses or system. Dispose of fluid
IAW local policy and ordinances. Ensure all spills are cleaned up.
Note routing of hoses to aid installation.
0272-2