TM 5-2410-240-10
0012
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued
LOCATION
ITEM TO BE
CHECKED
OR
EQUIPMENT NOT
ITEM
MAN-
SERVICED
PROCEDURE
READY/AVAILABLE IF:
NO.
INTERVAL HOURS
WARN I N G
Lubricating oil is very slppery. Immediately wipe up any
i
spills.
Refer to local procedures and plans for preventing and
responding to fluid spills and leaks. Comply with local pro-
cedures and plans when disposing of cleanup material
and leaked or spilled fluids.
Failure to follow this warning may c use injury.
a
7
Before
0.2
Engine Oil
a. Clean area around engine oil
Oil level is low or Class III
Level
level gauge and fill cap.
leak is evident.
b. Remove oil level gauge; clean,
and reinstall. Remove oil level
gauge and check level of oil.
Maintain oil level between the
marks on oil level gauge.
c. Add Oil, lubricating, OE/HDO
lubricating, OE/HDO 5W/40
lubricating, OE/HDO-15/40
lubricating, OEA-30 Arctic
through filler opening.
d. Clean oil filler cap, then
reinstall.