Figure 4. Fuel Shutoff Valve.
Figure 5. Engine Oil Level Check.

Operator Manual D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  101    102    103    104    105  106  107    108    109    110    111  
img
. . . . .
TM 5-2410-240-10
0012
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued
LOCATION
ITEM TO BE
CHECKED
OR
EQUIPMENT NOT
ITEM
MAN-
SERVICED
PROCEDURE
READY/AVAILABLE IF:
NO.
INTERVAL HOURS
WARN I N G
Lubricating oil is very slppery. Immediately wipe up any
i
spills.
Refer to local procedures and plans for preventing and
responding to fluid spills and leaks. Comply with local pro-
cedures and plans when disposing of cleanup material
and leaked or spilled fluids.
Failure to follow this warning may c use injury.
a
7
Before
0.2
Engine Oil
a. Clean area around engine oil
Oil level is low or Class III
Level
level gauge and fill cap.
leak is evident.
b. Remove oil level gauge; clean,
and reinstall. Remove oil level
gauge and check level of oil.
Maintain oil level between the
marks on oil level gauge.
c. Add Oil, lubricating, OE/HDO
30 (WP 0022, Item 11), Oil,
lubricating, OE/HDO 5W/40
(WP 0022, Item 13), Oil,
lubricating, OE/HDO-15/40
(WP 0022, Item 14), or Oil,
lubricating, OEA-30 Arctic
(WP 0022, Item 15) as required
through filler opening.
d. Clean oil filler cap, then
reinstall.
0012-8