Figure 38. Flood Lamp and Bulb Connector Terminals.
Figure 40. Front Flood Lamp Fuse Top Terminal.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  705    706    707    708    709  710  711    712    713    714    715  
img
.
TM 5-2410-240-23-1
0021
Table 1. Cab Troubleshooting Without Codes. - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6. Front Flood Lamp(s) Will Not
5. Using a digital multimeter,
Voltage Within 18 to 26 Volts -
Work - Continued
measure for voltage (WP
Proceed to Test Step 8.
0283) between front flood
Voltage Not Within 18 to 26
lamp fuse bottom terminal C3
Volts - Replace fuse block and
(Figure 39) and ground.
circuit breaker panel (WP 0201).
Verify proper operation of flood
lamps (TM 5-2410-240-10).
Figure 39. Front Flood Lamp Fuse Bottom Terminal.
0021