Figure 39. Front Flood Lamp Fuse Bottom Terminal.
Table 1. Cab Troubleshooting Without Codes. - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  706    707    708    709    710  711  712    713    714    715    716  
img
.
TM 5-2410-240-23-1
0021
Table 1. Cab Troubleshooting Without Codes. - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6. Front Flood Lamp(s) Will Not
Test Step 8. Test for Open Front
Work - Continued
Flood Lamp Fuse.
Using a digital multimeter,
Voltage Within 18 to 26 Volts -
measure for voltage (WP 0283)
Proceed to Test Step 9.
between front flood lamp fuse top
Voltage Not Within 18 to 26
terminal C2 (Figure 40) and
Volts - Turn battery disconnect
ground.
switch to OFF position (TM 5-
2410-240-10).
Remove front flood lamp fuse from
fuse block and discard fuse.
Proceed to Test Step 17.
Figure 40. Front Flood Lamp Fuse Top Terminal.
0021
0021-105