Table 1. Cab Troubleshooting Without Codes. - Continued.
Figure 52. Flood Lamp and Bulb Connector Terminals.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  756    757    758    759    760  761  762    763    764    765    766  
img
. . . .
TM 5-2410-240-23-1
0021
Table 1. Cab Troubleshooting Without Codes. - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
7. Rear Flood Lamp(s) Will Not
Test Step 19. Test for Shorted
Work - Continued
607-PK Flood Lamp Relay
Output Circuit Inside LH Rear
Flood Lamp.
1. Disassemble flood lamp (WP
0257).
2. Using digital multimeter, test
No Continuity - Assemble flood
for continuity (WP 0283)
lamp (WP 0257).
between bulb terminal 1 and
Proceed to Test Step 20.
bulb terminal 2 (Figure 52).
Continuity - Replace LH rear
flood lamp (WP 0257).
Install RH rear flood lamp on
machine (WP 0257).
Connect C-C31 (WP 0018,
Figure 28) on flood lamp relay
(WP 0018, Figure 55).
For D6K Dozer with Ripper, install
ripper operation control handle
(WP 0218). For D6K Dozer with
Winch, install winch operation
control handle (WP 0217).
Connect FP-C5 (WP 0018,
Figure 170) on C-C40 (WP 0018,
Figure 30) (WP 0201). Install three
new tiedown straps on fuse block
and circuit breaker panel wiring
harness and machine as noted
during removal.
Install fuse panel side cover on
machine (TM 5-2410-240-10).
Install new rear flood lamp fuse on
fuse block.
Install fuse panel front cover on
machine (TM 5-2410-240-10).
Verify proper operation of flood
lamps (TM 5-2410-240-10).