Figure 52. Flood Lamp and Bulb Connector Terminals.
Table 1. Cab Troubleshooting Without Codes. - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  758    759    760    761    762  763  764    765    766    767    768  
img
. . . .
TM 5-2410-240-23-1
0021
Table 1. Cab Troubleshooting Without Codes. - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
7. Rear Flood Lamp(s) Will Not
Test Step 20. Test for Shorted
Work - Continued
607-PK Flood Lamp Relay
Output Circuit Inside RH Rear
Flood Lamp.
1. Disassemble flood lamp (WP
0257).
No Continuity - Assemble flood
2. Using digital multimeter, test
for continuity (WP 0283)
lamp (WP 0257).
between bulb terminal 1 and
Install RH rear flood lamp and LH
bulb terminal 2 (Figure 52).
rear flood lamp on machine
(WP 0261).
Replace flood lamp relay (WP
0018, Figure 55).
For D6K Dozer with Ripper, install
ripper operation control handle
(WP 0223). For D6K Dozer with
Winch, install winch operation
control handle (WP 0217).
Connect FP-C5 (WP 0018,
Figure 170) on C-C40 (WP 0018,
Figure 30) (WP 0201). Install three
new tiedown straps on fuse block
and circuit breaker panel wiring
harness and machine as noted
during removal.
Install fuse panel side cover on
machine (TM 5-2410-240-10).
Install new rear flood lamp fuse on
fuse block.
Install fuse panel front cover on
machine (TM 5-2410-240-10).
Verify proper operation of flood
lamps (TM 5-2410-240-10).