Figure 53. Flood Lamp and Bulb Connector Terminals.
Table 2. Cab Troubleshooting With Codes.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  761    762    763    764    765  766  767    768    769    770    771  
img
. . . . .
TM 5-2410-240-23-1
0021
Table 1. Cab Troubleshooting Without Codes. - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
7. Rear Flood Lamp(s) Will Not
5. Using digital multimeter, mea-
Resistance 5.0 Ohms or Greater
Work - Continued
sure resistance (WP 0283)
- Replace lower cab wiring
between C-C40 terminal 7
harness (WP 0228).
(WP 0018, Figure 30) and C-
Install fuse panel front cover on
C31 terminal 1 (WP 0018,
machine (TM 5-2410-240-10).
Figure 28).
Verify proper operation of flood
lamps (TM 5-2410-240-10).
Resistance Less Than 5.0 Ohms
- Replace fuse block and circuit
breaker panel wiring harness
(WP 0201).
Connect C-C31 (WP 0018,
Figure 28) on flood lamp relay (WP
0018, Figure 55).
For D6K Dozer with Ripper, install
ripper operation control handle
(WP 0218). For D6K Dozer with
Winch, install winch operation
control handle (WP 0217).
Verify proper operation of flood
lamps (TM 5-2410-240-10).
0021-160