Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0070-04 Parking Brake Switch Volt-
11. Using digital multimeter, test
No Continuity - Replace platform
age Below Normal - Continued
for continuity (WP 0283)
harness (WP 0150, WP 0155).
between PL-C1 (WP 0018,
Ensure all harness connectors are
Figure 214) harness connec-
reconnected. Verify proper opera-
tor terminal 12 and PL-C4 (WP
tion of machine (TM 5-2410-240-
0018, Figure 217) equipment
10).
ECM J1 terminal 33.
Continuity - Proceed to step 12.
12. Using digital multimeter, test
No Continuity - Replace platform
for continuity (WP 0283)
harness (WP 0150, WP 0155).
between PL-C1 (WP 0018,
Ensure all harness connectors are
Figure 214) harness connec-
reconnected. Verify proper opera-
tor terminal 13 and PL-C4 (WP
tion of machine (TM 5-2410-240-
0018, Figure 217) equipment
10).
ECM J1 terminal 34.
Continuity - Proceed to step 13.
13. Using digital multimeter, test
No Continuity - Proceed to
for continuity (WP 0283)
step 14.
between PL-C4 (WP 0018,
Continuity - Replace platform har-
Figure 217) equipment ECM
ness (WP 0150, WP 0155).
J1 terminal 33 and all other
Ensure all harness connectors are
terminals in harness connec-
reconnected. Verify proper opera-
tor PL-C4 (WP 0018, Figure
tion of machine (TM 5-2410-240-
217).
10).
14. Using digital multimeter, test
No Continuity - Replace machine
for continuity (WP 0283)
ECM (WP 0147, WP 0149).
between PL-C4 (WP 0018,
Ensure all harness connectors are
Figure 217) equipment ECM
reconnected. Verify proper opera-
J1 terminal 34 and all other
tion of machine (TM 5-2410-240-
terminals in harness connec-
10).
tor PL-C4 (WP 0018,
Continuity - Replace platform har-
Figure 217).
ness (WP 0150, WP 0155).
Ensure all harness connectors are
reconnected. Verify proper opera-
tion of machine (TM 5-2410-240-
10).
N OT E
0298-03 Brake Pedal Position Switch
Voltage Above Normal
Always inspect harness connectors that are involved in circuit.
Poor connections can often be the cause of an electrical circuit
problem. Verify that all connections in the circuit are clean and
secure, and connections are in good condition. If a problem with
a connection is found, correct problem and verify diagnostic code
is active before performing this procedure.
Tag wiring harnesses to aid installation.
Perform this test only if condition is active.
1. Turn ignition switch and bat-
tery disconnect switch to OFF
position (TM 5-2410-240-10).
0021-165