Table 2. Cab Troubleshooting With Codes. - Continued.
Table 2. Cab Troubleshooting With Codes. - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  770    771    772    773    774  775  776    777    778    779    780  
img
. . . . . . . . . . .
TM 5-2410-240-23-1
0021
Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0298-04 Brake Pedal Position Switch
8. Using digital multimeter, test
No Continuity - Proceed to step 6.
Voltage Below Normal Continued
for continuity (WP 0283)
Continuity - Replace lower cab
between harness connector
harness (WP 0228). Ensure all
C-C12 (WP 0018, Figure 22)
harness connectors are recon-
terminal 36 and all other termi-
nected. Verify proper operation of
nals in C-C12
machine (TM 5-2410-240-10).
(WP 0018, Figure 22).
9. Using digital multimeter, test
No Continuity - Proceed to
for continuity (WP 0283)
step 10.
between harness connector
Continuity - Replace lower cab
C-C12 (WP 0018, Figure 22)
harness (WP 0228). Ensure all
terminal 37 and all other termi-
harness connectors are recon-
nals in C-C12
nected. Verify proper operation of
(WP 0018, Figure 22).
machine (TM 5-2410-240-10).
10. Disconnect harness connec-
tor PL-C5 (WP 0018, Figure
218) from equipment ECM J2.
11. Using digital multimeter, test
No Continuity - Replace platform
for continuity (WP 0283)
harness (WP 0150, WP 0155).
between harness connector
Ensure all harness connectors are
PL-C5 (WP 0018, Figure 218)
reconnected. Verify proper opera-
terminal 28 and harness con-
tion of machine (TM 5-2410-240-
nector PL-C1 (WP 0018, Fig-
10).
ure 214) terminal 37.
Continuity - Proceed to step 12.
12. Using digital multimeter, test
No Continuity - Replace platform
for continuity (WP 0283)
harness (WP 0150, WP 0155).
between harness connector
Ensure all harness connectors are
PL-C5 (WP 0018, Figure 218)
reconnected. Verify proper opera-
terminal 23 and harness con-
tion of machine (TM 5-2410-240-
nector PL-C1 (WP 0018, Fig-
10).
ure 214) terminal 36.
Continuity - Proceed to step 13.
13. Using digital multimeter, test
No Continuity - Proceed to
for continuity (WP 0283)
step 14.
between PL-C5 (WP 0018,
Continuity - Circuits are shorted -
Figure 218) equipment ECM
Replace platform harness
J2 terminal 28 and all other
(WP 0150, WP 0155). Ensure all
terminals in harness connec-
harness connectors are recon-
tor PL-C5 (WP 0018, Figure
nected. Verify proper operation of
218).
machine (TM 5-2410-240-10).