TM 5-2410-240-23-1
0021
Table 2. Cab Troubleshooting With Codes. - Continued.
0021
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0490-04 Hydraulic Lockout Switch
Voltage Below Normal - Continued
for continuity (WP 0283)
ECM (WP 0147, WP 0149).
Ensure all harness connectors are
Figure 218) equipment ECM
reconnected. Verify proper opera-
J2 terminal 47 and all other
tion of machine (TM 5-2410-240-
terminals in harness connec-
10).
218).
ness (WP 0150, WP 0155).
Ensure all harness connectors are
reconnected. Verify proper opera-
tion of machine (TM 5-2410-240-
10).
N OT E
0779-03 A/C Recirc Temp Sensor
Voltage Above Normal
Always inspect harness connectors that are involved in circuit.
Poor connections can often be the cause of an electrical circuit
problem. Verify that all connections in circuit are clean and
secure, and connections are in good condition. If a problem with
connection is found, correct problem and verify diagnostic code
is active before performing this procedure.
Tag wiring harnesses to aid installation.
Perform this test only if condition is active.
1. Turn ignition switch and bat-
tery disconnect switch to OFF
position (TM 5-2410-240-10).
2. Disconnect harness connec-
40) from A/C recirculation tem-
perature sensor.
3. Install jumper wire between
terminal 1 and terminal 2.
4. Turn battery disconnect switch
and ignition switch to ON posi-
tion (TM 5-2410-240-10).
N OT E
Wait at least 30 seconds for diagnostic codes to become active.
5. Check for active diagnostic
0779-03 Remains Active - Pro-
ceed to step 6.
0779-04 Becomes Active -
Replace A/C temperature sensor
(WP 0251). Ensure all harness
connectors are reconnected. Verify
proper operation of machine (TM
5-2410-240-10).