• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1179    1180    1181    1182    1183  1184  1185    1186    1187    1188    1189  
img
. . . . . . . .
TM 5-2410-240-23-1
0023
Table 2. Blade, Winch, and Ripper Troubleshooting With Codes - Continued.
0023
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2268-06 Winch Free-Spool
3. Disconnect winch solenoid wiring
Solenoid Current Above
harness connector WC-C2 (WP
Normal - Continued
0018, Figure 249) from platform
wiring harness connector PL-C33
(WP 0018, Figure 233) (WP
0137).
4. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-240-10).
5. Check for active code 2268-05 or
Code 2268-06 Remains Active - Pro-
2268-06 in machine control D6K
ceed to Test Step 3.
ECM (WP 0016).
Code 2268-06 Becomes Inactive
and 2268-05 Becomes Active -
Replace winch solenoid wiring har-
ness (WP 0137).
Proceed to step 6.
6. Using MSD (WP 0016), select
Code 2268-06 Active - Repeat trou-
machine control D6K ECM and
bleshooting code from the beginning.
verify 2268-06 is not active.
Code 2268-06 Not Active - Trouble-
shooting complete.
Test Step 3. Test F870-BU Free-
Spool Solenoid Supply Circuit for
Short to Other Circuits in Platform
Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
2. Disconnect platform wiring har-
ness connector PL-C2 (WP 0018,
Figure 215) from equipment ECM
(WP 0148).
3. Disconnect platform wiring har-
ness connector PL-C5 (WP 0018,
Figure 218) from ECM J2 (WP
0149).
4. Disconnect platform wiring har-
ness connector PL-C4 (WP 0018,
Figure 217) from ECM J1 (WP
0149).
0023-222