Figure 12. Fuel Outlet Connector.
Figure 16. Fuel Return Connector.

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  44    45    46    47    48  49  50    51    52    53    54  
img
.
TM 5-2410-240-23-3
0175
ASSEMBLY
000175
1. Install two new O-rings (Figure 14, Items 2 and 4) on check valve (Figure 14, Item 3), and install check valve
(Figure 14, Item 3) on fuel tank (Figure 14, Item 1).
Figure 14. Fuel Outlet Check Valve.
0175
2. Install fuel tank outlet connector (Figure 15, Item 1) on check valve (Figure 15, Item 2).
Figure 15. Fuel Outlet Connector.
0175
0175-12