TM 5-2410-240-23-3
0190
INSTALLATION CONTINUED
N OT E
If equipped with arctic kit heater, perform steps 2 through 5. If not equipped with arctic kit
heater, proceed to step 6.
2. Measure 0.78 in. (20 mm) from edge of right rear access panel (Figure 10, Item 1) and mark. Measure 2.2 in.
(58 mm) up from bend in right rear access panel and mark.
WARN I N G
Take the following precautions before grinding,cutting, or welding any equipment that has
been CARC-coated:
Wear protective equipment (e.g., goggles, gloves, apron) when grinding or
sanding CARC-coated equipment. DO NOT leave any skin exposed.
Use high-efficiency air-purifying respirators when grinding or sanding CARC-
coated equipment.
Never weld or cut CARC-coated equipment; grind or sand off CARC paint
completely before welding.
CARC paint contains isocyanate (HDI), which is highly irritating to the skin and
respiratory system. High concentrations of HDI can produce itching and reddening
of the skin, a burning sensation in the throat and nose, and watering of the eyes.
In extreme concentrations, HDI can cause coughing, shortness of breath, pain
during respiration, increased sputum production, and chest tightness.
Failure to follow these warnings may result in injury or death to personnel.
3. Prepare site IAW welding procedures.
4. Weld boss (Figure 10, Item 2) on right rear access panel (Figure 10, Item 1).
5. Preserve site IAW welding procedures.
Figure 10. Weld Boss.
0190