Figure 9. A/C Condenser Fan Wiring Harness.
Figure 11. A/C Condenser Mounting Bracket at Back of Cab Left Side.

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  524    525    526    527    528  529  530    531    532    533    534  
img
.
TM 5-2410-240-23-3
0229
REMOVAL CONTINUED
C AU T I O N
Cap or plug all A/C hoses and fittings during removal to protect against contamination.
Failure to follow this caution may result in equipment damage.
N OT E
Tag and mark A/C hoses to aid installation.
Note orientation of fittings to aid installation.
18. Loosen fitting (Figure 10, Item 7).
19. Loosen fitting (Figure 10, Item 6).
20. Remove fitting (Figure 10, Item 7) from fitting (Figure 10, Item 4).
21. Remove fitting (Figure 10, Item 6) from fitting (Figure 10, Item 5).
22. Remove bolt (Figure 10, Item 3), washer (Figure 10, Item 2), bracket (Figure 10, Item 8) and spacer
(Figure 10, Item 1) from back of cab (Figure 10, Item 9).
Figure 10. A/C Condenser Quick Disconnect at Back of Cab.
0229
0229-9