Figure 10. A/C Condenser Quick Disconnect at Back of Cab.
Figure 12. A/C Condenser Mounting Bracket at Back of Cab Right Side.

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  525    526    527    528    529  530  531    532    533    534    535  
img
.
TM 5-2410-240-23-3
0229
REMOVAL CONTINUED
WARN I N G
Use extreme caution when handling heavy parts. Provide adequate support and use
assistance during procedure. Ensure any lifting device used is in good condition and of
suitable load capacity. Keep clear of heavy parts supported only by lifting device. Failure to
follow this warning may result in injury or death to personnel.
N OT E
Condenser assembly weighs approximately 45 lb (20 kg).
23. Using lifting device, support A/C condenser and mounting bracket assembly.
24. Remove three bolts (Figure 11, Item 2) and washers (Figure 11, Item 1) from back of cab (Figure 11, Item 5).
25. Remove bolt (Figure 11, Item 3) and washer (Figure 11, Item 4) from back of cab (Figure 11, Item 5).
Figure 11. A/C Condenser Mounting Bracket at Back of Cab Left Side.
0229
0229-10