TM 5-2410-240-23-3
0254
CHARGING - CONTINUED
2. Install red high-side hose (Figure 3, Item 1) on discharge (high) side of A/C compressor.
C AU T I O N
DO NOT invert R-134a refrigerant tank while charging A/C system. Liquid refrigerant
entering low side of A/C system will permanently damage compressor.
3. Follow recovery station OEM instructions and charge A/C system with R-134a refrigerant. Refrigerant capacity
is 3.3 lb (1.5 kg).
4. Once charging is complete, disconnect blue low-side hose (Figure 3, Item 2) from suction (low) side of A/C
compressor and red high-side hose (Figure 3, Item 1) from discharge (high) side of A/C compressor.
5. Operate A/C system to verify correct operation (TM 5-2410-240-10).
Figure 3. Charging Hook-Up.
0254
END OF TASK
FOLLOW-ON TASKS
000254
Verify correct operation of machine (TM 5-2410-240-10).
END OF TASK
END OF WORK PACKAGE