Figure 6. Negative Arctic Battery Terminal Removal (Right Battery).
Figure 8. Positive Arctic Battery Terminal Removal (Right Battery).

Field Maintenance Manual 3 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1066    1067    1068    1069    1070  1071  1072    1073    1074    1075    1076  
img
.
TM 5-2410-240-23-3
0276
REMOVAL CONTINUED
12. Lift positive arctic battery jumper terminal cover (Figure 7, Item 1) from positive arctic battery terminal
(Figure 7, Item 2).
N OT E
Tag battery cables to aid installation.
13. Loosen positive arctic battery jumper terminal nut (Figure 7, Item 3) and remove positive arctic battery jumper
terminal (Figure 7, Item 2) from right arctic battery (Figure 7, Item 4).
Figure 7. Positive Arctic Battery Terminal Removal (Right Battery).
0276
0276-6