TM 5-2410-240-23-3
0282
a. Do not remove dowel pins or studs unless they are loose, bent, broken, or otherwise damaged.
b. Do not pull bearings or bushings unless damaged. If you must get at parts behind them, pull out bearings
or bushings carefully.
c.
Replace all gaskets, seals, preformed packing, O-rings, cotter pins, spring pins, self-locking nuts, and
END OF TASK
CLEANING INSTRUCTIONS
000282
WARN I N G
Solvent cleaning compound MIL-PRF-680 TypeIII is an environmentally compliant and
low-toxicity material. However, it may be irritating to the eyes and skin. Use protective
gloves and goggles. Use in well-ventilated areas. Keep away from open flames and other
sources of ignition. When not using MIL-PRF-680 solvents, ensure MIL-PRF-680 solvent
container is sealed. Store, handle and dispose of unused and spent solvents in
accordance with local procedures and plans.
Eye shields must be worn whencleaning with a wire brush. Flying rust and metal particles
may cause injury.
Particles blown by compressed air are hazardous. Use a maximum of 30 psi (207 kPa)
when cleaning components. DO NOT exceed 15 psi (103 kPa) nozzle pressure when
drying parts with compressed air. DO NOT direct compressed air against human skin.
Make sure air stream is directed away from user and other personnel in the area. To
prevent injury, user must wear protective goggles or face shield.
Failure to follow these warnings ma result in injury to personnel.
y
N OT E
Fire extinguishers should be placed n arby when using solvent cleaning compound.
e
Cloths or rags saturated with solvent cleaning compound must be disposed of IAW
authorized facilities' procedures.
0282-4