TM 5-2410-240-23-3
0283
MILITARY CONNECTOR REPAIR
000283
1. Slide shell (Figure 3, Item 1) back on wire (Figure 3, Item 2) to expose sleeve (Figure 3, Item 5).
2. Remove sleeve (Figure 3, Item 5) from terminal (Figure 3, Item 4) by pulling sleeve forward.
3. If defective, remove terminal (Figure 3, Item 4) from wire (Figure 3, Item 2) by cutting through wire just behind
terminal.
N OT E
Perform steps 4 through 7 only if terminal was removed.
4. Using wire stripping tool, strip insulation from wire (Figure 3, Item 2) to expose length of metal strands
(Figure 3, Item 3) equal to depth of terminal (Figure 3, Item 4).
5. Using crimping tool, securely crimp terminal (Figure 3, Item 4) to metal strands (Figure 3, Item 3) of wire
(Figure 3, Item 2).
6. Install sleeve (Figure 3, Item 5) on terminal (Figure 3, Item 4) by pushing sleeve over front of terminal until fully
seated.
7. Slide shell (Figure 3, Item 1) up wire (Figure 3, Item 2) and over sleeve (Figure 3, Item 5).
Figure 3. Military Connector Repair.
0283