C AU T I O N
Wipe area clean around hydraulic system, and cap all hydraulic hose ends and
component connections during removal to protect against contamination. Failure to follow
this caution may cause damage to equipment.
HYDRAULIC PRESSURE TEST HOSE AND GAUGE
000291
1. Install adapter (Figure 1, Item 2) on pressure gauge (Figure 1, Item 1).
2. Install fitting (Figure 1, Item 3) on adapter (Figure 1, Item 2).
3. Install quick-connect coupler (Figure 1, Items 5 and 6) on each end of hose (Figure 1, Item 4).
4. Install hose (Figure 1, Item 4) on gauge (Figure 1, Item 1).
Figure 1. Hydraulic Pressure Test Hose and Gauge.
0291
END OF TASK
HYDRAULIC PRESSURE TEST JUMPER HOSE
000291
1. Install quick-connect coupler (Figure 2, Items 1 and 3) on each end of hose (Figure 2, Item 2).
Figure 2. Hydraulic Pressure Test Jumper Hose.
0291
END OF TASK