0010
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
0.
ENGINE SYSTEM CONTINUED
2. ENGINE CANNOT REACH TOP ENGINE RPM.
Step 1.
Check for diagnostic service codes.
a.
If diagnostic service codes are present, notify Field Maintenance.
b.
If no diagnostic service codes are present, go to step 2.
Step 2.
Check fuel supply.
a.
Add fuel as necessary (WP 0012).
b.
Verify fuel is not solidified (ambient temperatures below 32F [0C]).
c.
If problem persists, go to step 3.
Step 3.
Check air filters.
a.
Clean or replace air filters (WP 0014).
b.
If problem persists, notify Field Maintenance.
3. ENGINE CRANKS BUT WILL NOT START.
Step 1.
Check for diagnostic service codes.
a.
If diagnostic service codes are present, notify Field Maintenance.
b.
If there are no diagnostic codes, go to step 2.
Step 2.
Verify fuel level.
a.
Add fuel as necessary (WP 0012).
b.
If problem persists, go to step 3.
Step 3.
Check air filters.
a.
Clean or replace air filters (WP 0014).
b.
If problem persists, go to step 4.
Step 4.
Check circuit breakers.
a.
Reset circuit breakers (WP 0018).
b.
If problem persists, notify Field Maintenance.