TM 5-2410-241-10
0012
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.
0012
LOCATION
ITEM TO
CHECK/
NOT FULLY MISSION
ITEM
MAN-
SERVICE
PROCEDURE
CAPABLE IF:
NO.
INTERVAL HOURS
Fuel Tank
68
Every 250
WARN I N G
Water and Sed-
Engine
iment Drain
Hours or
Monthly
DO NOT smoke or permit any open flame in area of
machine while you are servicing fuel system.
Operating personnel must wearfuel-resistant gloves when
handling fuels. If exposed to fuel, promptly wash exposed
skin and change fuel-soaked clothing.
Failure to follow these warnngs may cause injury or death
i
to personnel or damage to equipment.
N OT E
Place portable fire extinguisher within reach prior to
servicing fuel system.
a. Place suitable container below
fuel tank drain hose.
b. Open drain valve and allow
water and sediment to drain.
c. Continue draining until only fuel
drains from hose, then close drain
valve.
d. Dispose of drained fluids IAW
unit SOP.
0012-44