CHAPTER 5. MAINTENANCE INSTRUCTIONS
ENGINE PRIMARY AND SECONDARY AIR FILTER ELEMENTS MAINTENANCE

Operators Manual D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  158    159    160    161    162  163  164    165    166    167    168  
img
. . .
2
TM 5-2410-241-10
0013
OPERATOR MAINTENANCE
-
DOME LAMP BULB REPLACEMENT
001
3
Removal, Installation
INITIAL SETUP
Materials/Parts
Estimated Time to Complete
0
0
Dome lamp bulb
0.2 Hr
0
0
Equipment Condition
0
Machine parked (WP 0005)
0
REMOVAL
00013
1. Remove dome lamp cover (Figure 1, Item 1) from dome lamp.
2. Remove dome lamp bulb (Figure 1, Item 2) by pushing in slightly and turning bulb to the left to disengage bulb
locking lugs. Pull bulb out of socket (Figure 1, Item 3). Discard bulb.
END OF TASK
INSTALLATION
00013
1. Install new bulb (Figure 1, Item 2) in socket (Figure 1, Item 3), push in slightly, and turn bulb clockwise to the
right to engage bulb locking lugs.
2. Install cover (Figure 1, Item 1).
Figure 1. Dome Lamp Bulb Replacement.
0013
END OF TASK
END OF WORK PACKAGE
0013-1/(2 blank)