Table 2. Engine Troubleshooting Procedures. - Continued
Table 2. Engine Troubleshooting Procedures. - Continued

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  397    398    399    400    401  402  403    404    405    406    407  
img
. . . . . . . . .
TM 5-2410-241-23-1
0019
Table 2. Engine Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
262-3 5 Volt DC Power Sup-
13. Check for Diagnostic Codes or
1. If active code 262-3 code is pres-
ply Short to +Batt -
Event Codes (WP 0013).
ent, proceed to step 14.
Continued
2. If 262-3 code is not active,
replace inlet manifold pressure
sensor (WP 0092). Ensure all har-
ness connectors are reconnected.
Verify correct operation of
machine (TM 5-2410-241-10).
14. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
15. Disconnect turbocharger inlet
pressure sensor connector V-C20
(WP 0018, Figure 37) from turbo
inlet pressure sensor (WP 0066).
16. Turn battery disconnect switch
and ignition switch to ON position
(TM 5-2410-241-10).
17. Check for Diagnostic Codes or
1. If active code 262-3 code is pres-
Event Codes (WP 0013).
ent, proceed to step 18.
2. If 262-3 code is not active,
replace turbo inlet pressure sen-
sor (WP 0066). Ensure all har-
ness connectors are reconnected.
Verify correct operation of
machine (TM 5-2410-241-10).
18. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-241-10).
19. Disconnect engine ECM connec-
tor N-C1 (WP 0018, Figure 2)
from ECM.
20. Using digital multimeter
1. If continuity is found, replace ECM
(WP 0296), test for continuity
harness (WP 0105). Ensure all
between pin 2 on engine ECM
harness connectors are recon-
connector N-C1 (WP 0018,
nected. Verify correct operation of
Figure 2) and all other pins on
machine (TM 5-2410-241-10).
engine ECM connector N-C1
2. If continuity is not found proceed
(WP 0018, Figure 2).
to step 21.
21. Using digital multimeter
1. If continuity is found, replace ECM
(WP 0296), test for continuity
harness (WP 0105). Ensure all
between pin 3 on engine ECM
harness connectors are recon-
connector N-C1 (WP 0018,
nected. Verify correct operation of
Figure 2) and all other pins on
machine (TM 5-2410-241-10).
engine ECM connector N-C1
2. If continuity is not found, proceed
(WP 0018, Figure 2).
to step 22.
0019-66