TM 5-2410-241-23-1
0020
Table 1. Powertrain Troubleshooting Procedures - Continued.
0020
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
444-5 Starter Motor Relay
Voltage Below Normal -
0296), test for continuity between
to step 17.
Continued
pin 4 on platform harness connec-
2. If continuity is found, replace plat-
form harness (WP 0209). Ensure
and all other pins in platform har-
all harness connectors are recon-
nected. Verify correct operation of
Figure 21).
machine (TM 5-2410-241-10).
0296), test for continuity between
to step 18.
pin 5 on platform harness connec-
2. If continuity is found, replace plat-
form harness (WP 0209). Ensure
and all other pins in platform har-
all harness connectors are recon-
nected. Verify correct operation of
Figure 21).
machine (TM 5-2410-241-10).
18. Remove fuse panel (WP 0176).
19. Disconnect fuse panel harness
start relay connector A-C3 (WP
0018, Figure 51) from start relay
(WP 0176).
1. If continuity is found, proceed to
0296), test for continuity between
step 21.
pin 4 on fuse panel wiring harness
fuse panel harness (WP 0176).
22) and pin 1 on fuse panel har-
Ensure all harness connectors are
ness start relay connector A-C3
reconnected. Verify correct opera-
tion of machine (TM 5-2410-241-
10).
1. If continuity is found, proceed to
0296), test for continuity between
step 22.
pin 5 on fuse panel wiring harness
fuse panel harness (WP 0176).
22) and pin 2 on fuse panel har-
Ensure all harness connectors are
ness start relay connector A-C3
reconnected. Verify correct opera-
tion of machine (TM 5-2410-241-
10).
0296), test for continuity between
to step 23.
pin 4 on fuse panel wiring harness
2. If continuity is found, replace fuse
panel harness (WP 0176). Ensure
22) and all other pins in fuse panel
all harness connectors are recon-
wiring harness connector A-C1
nected. Verify correct operation of
machine (TM 5-2410-241-10).
0020-65