TM 5-2410-241-23-1
0020
Table 1. Powertrain Troubleshooting Procedures - Continued.
0020
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
444-6 Starter Motor Relay
1. If continuity is NOT found, proceed
Current Above Normal -
0296), test for continuity between
to step 19.
Continued
pin 4 on platform harness connec-
2. If continuity is found, replace plat-
form harness (WP 0209). Ensure
and all other pins in platform har-
all harness connectors are recon-
nected. Verify correct operation of
Figure 21).
machine (TM 5-2410-241-10).
1. If continuity is NOT found, proceed
0296), test for continuity between
to step 20.
pin 4 on platform harness connec-
2. If continuity is found, replace plat-
form harness (WP 0209). Ensure
and machine ground.
all harness connectors are recon-
nected. Verify correct operation of
machine (TM 5-2410-241-10).
1. If continuity is NOT found, proceed
0296), test for continuity between
to step 21.
pin 5 on platform harness connec-
2. If continuity is found, replace plat-
form harness (WP 0209). Ensure
and all other pins in platform har-
all harness connectors are recon-
nected. Verify correct operation of
Figure 21).
machine (TM 5-2410-241-10).
21. Remove fuse panel (WP 0176).
22. Disconnect fuse panel harness
start relay connector A-C3 (WP
0018, Figure 51) from start relay
(WP 0176).
1. If continuity is found, proceed to
0296), test for continuity between
step 24.
pin 4 on fuse panel wiring harness
fuse panel harness (WP 0176).
Figure 22) and pin 1 on fuse panel
Ensure all harness connectors are
harness start relay connector A-
reconnected. Verify correct opera-
tion of machine (TM 5-2410-241-
10).
1. If continuity is found, proceed to
0296), test for continuity between
step 25.
pin 5 on fuse panel wiring harness
fuse panel harness (WP 0176).
Figure 22) and pin 2 on fuse panel
Ensure all harness connectors are
harness start relay connector A-
reconnected. Verify correct opera-
tion of machine (TM 5-2410-241-
10).
0020-69