Table 1. Cab Troubleshooting Procedures - Continued.
Table 1. Cab Troubleshooting Procedures - Continued.

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  814    815    816    817    818  819  820    821    822    823    824  
img
. . . .
TM 5-2410-241-23-1
0022
Table 1. Cab Troubleshooting Procedures - Continued.
0022
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Horn Does Not Operate -
12. Turn ignition switch and battery
Continued
disconnect switch to OFF position
(TM 5-2410-241-10).
13. Remove Fuse #13 (Figure 10,
Item 1) from fuse panel (TM 5-
2410-241-10).
Figure 10. Fuse #13.
0022
14. Using digital multimeter (WP
1. If continuity is found, install Fuse
0296), test for continuity between
#13 on fuse panel (TM 5-2410-
blades of Fuse #13.
241-10). Proceed to step 29.
2. If continuity is NOT found, replace
Fuse #13 (TM 5-2410-241-10).
Proceed to step 15.
15. Connect front lighting harness top
horn connector G-C4 (WP 0018,
Figure 156) on top horn (WP
0182).
16. Connect front lighting harness
bottom horn connector G-C5 (WP
0018, Figure 157) on bottom horn
(WP 0182).