Figure 17. Top of Fan Guard.
RADIATOR COOLING LINES REPLACEMENT

Field Maintenance Manual 1 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  1126    1127    1128    1129    1130  1131  1132    1133    1134    1135    1136  
img
. .
TM 5-2410-241-23-1
0050
INSTALLATION CONTINUED
N OT E
The following procedure is for the left lower bracket installation. Use this same procedure
for the right lower bracket installation.
15. Install lower bracket (Figure 18, Item 6), clip (Figure 18, Item 3), two washers (Figure 18, Item 2) and bolts
(Figure 18, Item 1) on machine.
16. Install two washers (Figure 18, Item 4) and bolts (Figure 18, Item 5) on lower bracket (Figure 18, Item 6).
Figure 18. Lower Brackets.
0050
END OF TASK
FOLLOW-ON TASKS
00050
1. Install A/C condenser (WP 0044).
2. Install V-belt set (Alternator) (WP 0098).
3. Install V-belt (A/C compressor) (WP 0096).
4. Verify correct operation of machine (TM 5-2410-241-10).
END OF TASK