Figure 20. Secondary Fuel Filter.
Figure 22. ECM Connection.

Field Maintenance Manual D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  18    19    20    21    22  23  24    25    26    27    28  
img
.
TM 5-2410-241-23-2
0057
INSTALL ENGINE ON STAND CONTINUED
N OT E
Tag and mark all cables to aid installation.
3. Remove nut (Figure 21, Item 2) and cable (Figure 21, Item 1) from starter motor solenoid (Figure 21, Item 4).
4. Remove nut (Figure 21, Item 5) and cable (Figure 21, Item 3) from starter motor solenoid (Figure 21, Item 4).
5. Remove nut (Figure 21, Item 8), and cable (Figure 21, Item 10) from starter (Figure 21, Item 6). Set cable
aside.
6. Remove cable (Figure 21, Item 7) and cable (Figure 21, Item 9) from starter (Figure 21, Item 6). Set cables
aside.
7. Remove nut (Figure 21, Item 11) and cable (Figure 21, Item 9) from engine.
Figure 21. Starter Connection.