TM 5-2410-241-23-2
0063
INSTALLATION
00063
N OT E
Install electrical connectors as tagged during removal.
1. Install new O-ring (Figure 2, Item 4) on air inlet temperature sensor (Figure 2, Item 2).
2. Install air inlet temperature sensor (Figure 2, Item 2) on aftercooler (Figure 2, Item 3).
3. Connect connector (Figure 2, Item 1) on air inlet temperature sensor (Figure 2, Item 2).
Figure 2. Air Inlet Temperature Sensor.
0063
END OF TASK
FOLLOW-ON TASKS
00063
1. Install engine enclosure right door guard (WP 0204).
2. Verify correct operation of machine (TM 5-2410-241-10).
END OF TASK
END OF WORK PACKAGE