Figure 13. Tank Return Line.
Figure 15. Fuel Return Line.

Field Maintenance Manual D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  858    859    860    861    862  863  864    865    866    867    868  
img
.
TM 5-2410-241-23-2
0157
FUEL SUPPLY AND RETURN LINE INSTALLATION CONTINUED
N OT E
Install fittings as noted during removal.
12. Install new O-ring (Figure 14, Item 10) and fitting (Figure 14, Item 9) on tank (Figure 14, Item 1).
13. Install new O-ring (Figure 14, Item 8) and valve (Figure 14, Item 7) on fitting (Figure 14, Item 9).
14. Install new O-ring (Figure 14, Item 6) and fitting (Figure 14, Item 5) on valve (Figure 14, Item 7).
15. Install new O-ring (Figure 14, Item 4), hose (Figure 14, Item 2) and tube nut (Figure 14, Item 3) on fitting
(Figure 14, Item 5).
Figure 14. Tank Supply Line.