0197
INSTALLATION
000197
WARN I N G
Lubricating/hydraulic oils used in performance of maintenance can be very slippery.
Immediately wipe up any spills. Failure to follow this warning may result in injury to
personnel.
N OT E
Install tubes and fittings as noted during removal.
It may be necessary to remove or loos n other hoses to gain access to bolts.
e
Install hoses through engine compartment into cab.
1. Remove caps and install two new O-rings (Figure 12, Item 3) on hoses (Figure 12, Item 4).
2. Connect two hoses (Figure 12, Item 4) to control valve (Figure 12, Item 2).
3. Install two flanges (Figure 12, Item 1), eight bolts (Figure 12, Item 5), and washers (Figure 12, Item 6) on two
hoses (Figure 12, Item 4).
Figure 12. Implement Valve.
0197
0197-12