Figure 9. Left Column Access Hole.
Figure 12. Cab Wiring Harness.

Field Maintenance Manual 3 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  647    648    649    650    651  652  653    654    655    656    657  
img
. .
TM 5-2410-241-23-3
0254
REMOVAL CONTINUED
N OT E
Tag and mark electrical connectors to aid installation.
Note wiring harness routing to aid installation.
Note location of tiedown sraps to aid installation.
t
23. Remove and discard tiedown straps (Figure 11, Item 1) from cab wiring harness (Figure 11, Item 2) and cab.
24. Remove two pieces of conduit (Figure 11, Items 4 and 5) from cab wiring harness (Figure 11, Item 2) at doors.
25. Remove cab wiring harness (Figure 11, Item 2) through access hole (Figure 11, Item 3) in cab cross member.
Figure 11. Cab Wiring Harness.
0254
END OF TASK
CLEANING AND INSPECTION
000254
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0295).
END OF TASK