Figure 7. Fuel Metering Pump.
Figure 9. Arctic Bracket.

Field Maintenance Manual 3 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  952    953    954    955    956  957  958    959    960    961    962  
img
.
TM 5-2410-241-23-3
0291
INSTALLATION CONTINUED
7. Install new O-ring (Figure 8, Item 9) on coolant pump (Figure 8, Item 7).
8. Install coolant pump (Figure 8, Item 7) and clamp (Figure 8, Item 8) on arctic kit heater (Figure 8, Item 10).
9. Connect connector (Figure 8, Item 6) to coolant pump (Figure 8, Item 7).
10. Install clip (Figure 8, Item 3) on intake tube (Figure 8, Item 5).
11. Install clip (Figure 8, Item 3), intake tube (Figure 8, Item 5), washer (Figure 8, Item 2), and bolt (Figure 8,
Item 1) on arctic kit heater (Figure 8, Item 10).
12. Install clamp (Figure 8, Item 4) on intake tube (Figure 8, Item 5).
13. Install intake tube (Figure 8, Item 5) on arctic kit heater (Figure 8, Item 10) and tighten clamp (Figure 8, Item 4).
Figure 8. Coolant Pump.