Figure 7. Arctic Kit Heater Fuel Shutoff Valve.
ARCTIC KIT FUEL METERING PUMP, HOSE, AND FITTING REPLACEMENT - Continued

Field Maintenance Manual 3 D7R Dozer Type I With Winch and Type II With Ripper
Page Navigation
  974    975    976    977    978  979  980    981    982    983    984  
img
.
TM 5-2410-241-23-3
0293
INSTALLATION CONTINUED
N OT E
Install fittings as noted during removal.
16. Install new O-ring (Figure 8, Item 2) on elbow (Figure 8, Item 14).
17. Install elbow (Figure 8, Item 14) and tube nut (Figure 8, Item 1) on T fitting (Figure 8, Item 3).
18. Install new O-ring (Figure 8, Item 13) on shutoff valve (Figure 8, Item 11).
19. Install new O-ring (Figure 8, Item 10) on elbow (Figure 8, Item 8).
20. Install shutoff valve (Figure 8, Item 11) and tube nut (Figure 8, Item 12) on elbow (Figure 8, Item 14).
21. Install elbow (Figure 8, Item 8) and tube nut (Figure 8, Item 9) on shutoff valve (Figure 8, Item 11).
22. Install fitting (Figure 8, Item 7) on elbow (Figure 8, Item 8).
23. Install nipple (Figure 8, Item 6) on fitting (Figure 8, Item 7).
24. Install clamp (Figure 8, Item 4) on fuel hose (Figure 8, Item 5)
25. Install fuel hose (Figure 8, Item 5) on nipple (Figure 8, Item 6).
26. Tighten clamp (Figure 8, Item 4) on fuel hose (Figure 8, Item 5).
27. Turn arctic fuel shutoff valve (Figure 8, Item 11) to ON position.
Figure 8. Arctic Kit Heater Fuel Shutoff Valve.
0293
END OF TASK
0293-10