TM 5-2410-240-23-1
0020
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
CID FMI CODE
Test or Inspection
Corrective Action
1705-05 Proportional Sole-
noid Valve (Forward Right
0283), test for continuity between
(WP 0147, WP 0149). Ensure all har-
Drive Pump) Current Below
pin 51 on platform harness ECM
ness connectors are reconnected.
Normal - Continued
Verify proper operation of machine
Figure 217) and all other pins on
(TM 5-2410-240-10).
platform harness ECM J2 connec-
harness (WP 0150, WP 0155).
Ensure all harness connectors are
reconnected. Verify proper operation
of machine (TM 5-2410-240-10).
N OT E
1705-06 Proportional Sole-
noid Valve (Forward Right
Always inspect the harness connectorsthat are involved in the circuit.
Drive Pump) Current Above
Poor connections can often be the cause of a problem in an electrical
Normal
circuit. Verify that all connections in the circuit are clean, secure and
that all connections are in good condition. If a problem with a
connection is found, correct the problem and verify that this diagnostic
code is active before performing this procedure.
Tag wiring harnesses to aid installation.
1705-06 Code Active - Proceed to
step 2.
machine control ECM and check
No Codes Active - The problem does
not exist at this time. Resume normal
operation.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
3. Disconnect pump harness RH for-
from RH forward pump solenoid.
4. Check for diagnostic codes (WP
1705-06 Code Active - Proceed to
step 5.
1705-05 Code Active - Replace RH
Ensure all harness connectors are
reconnected. Verify proper operation
of machine (TM 5-2410-240-10).
5. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).