Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.

Field Maintenance Manual 1 D6K Dozer Type I With Winch and Type II With Ripper
Page Navigation
  543    544    545    546    547  548  549    550    551    552    553  
img
. . . . . . . . .
TM 5-2410-240-23-1
0020
Table 2. Powertrain and Chassis Troubleshooting with Codes - Continued.
CID FMI CODE
Test or Inspection
Corrective Action
1705-03 Proportional Sole-
14. Using digital multimeter (WP
No Continuity - Replace machine
noid Valve (Forward Right
0283), test for continuity between
ECM (WP 0147, WP 0149). Ensure all
Drive Pump) Voltage Above
pin 51 on platform harness ECM
harness connectors are reconnected.
Normal - Continued
J1 connector PL-C4 (WP 0018,
Verify proper operation of machine
Figure 217) and all other pins on
(TM 5-2410-240-10).
platform harness ECM J2 connec-
Continuity - Replace platform wiring
tor PL-C5 (WP 0018, Figure 218).
harness (WP 0150, WP 0155).
Ensure all harness connectors are
reconnected. Verify proper operation
of machine (TM 5-2410-240-10).
N OT E
1705-05 Proportional Sole-
noid Valve (Forward Right
Always inspect harness connectors that are involved in circuit. Poor
Drive Pump) Current Below
connections can often be the cause of an electrical circuit problem.
Normal
Verify that all connections in circuit are clean, secure, and connections
are in good condition. If a problem with connection is found, correct
problem and verify diagnostic code is active before performing this
procedure.
Tag wiring harnesses to aid installation.
1703-05 Code Active - Proceed to
1. Connect MSD (WP 0016). Select
step 2.
machine control ECM and check
for diagnostic codes (WP 0013).
No Codes Active - The problem does
not exist at this time. Resume normal
operation.
2. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
3. Disconnect pump harness RH for-
ward pump solenoid connector
PH-C4 (WP 0018, Figure 208)
from RH forward pump solenoid.
4. Install a jumper wire between pins
1 and 2 on pump harness RH for-
ward pump solenoid connector
PH-C4 (WP 0018, Figure 208).
5. Check for diagnostic codes (WP
1705-05 Code Active - Proceed to
0013).
step 6.
1705-06 Code Active - Replace RH
forward pump solenoid (WP 0132).
Ensure all harness connectors are
reconnected. Verify proper operation
of machine (TM 5-2410-240-10).
6. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-2410-240-10).
0020-100