TM 5-2410-240-23-1
0021
Table 1. Cab Troubleshooting Without Codes. - Continued.
0021
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6. Front Flood Lamp(s) Will Not
Ring Terminal Defective -
Work - Continued
Replace upper cab wiring harness
(WP 0229).
Install LH (inner) front flood lamp
#2, LH (outer) front flood lamp #1,
RH (inner) front flood lamp #2, and
RH (outer) front flood lamp #1 on
machine (WP 0256).
27) on flood lamp relay #1 (WP
For D6K Dozer with Ripper, install
ripper operation control handle
(WP 0218). For D6K Dozer with
Winch, install winch operation
control handle (WP 0217).
Verify proper operation of flood
lamps (TM 5-2410-240-10).
No Problem Found - Install upper
cab wiring harness terminals on
ground point with mounting
hardware and tighten securely.
Proceed to Test Step 15.
Figure 41. Ground Point of Upper Cab Wiring Harness.
0021